2. OPERATION
– 50 –
Emergency traveling
If the machine doesn’t move when you operate the forward and reverse control lever while
the engine is running, there maybe a problem with the control system.
In this case, you may bypass the controller to temporarily drive the machine by following the
procedure below.
1) Push on the parking brake. Shut off the engine and make sure the emergency propel
switch is in the neutral position.
2) Identify the connectors “ PRO ” & “ EME ” between the valve blocks on the left side of the
machine.
3) Remove the plugs from connector “ PRO ” then exchange connectors “ PRO ” and “ EME
”.
4) Make sure the connectors are properly connected, close the hood but do not start the
engine until you have checked the surrounding area for obstacles.
Also make sure that the emergency switch and traveling direction of the machine are the
same. Now it will be safe to move the machine to a safe area.