2. OPERATION
– 62 –
– 63 –
IMPORTANT
When the machine controller malfunctions or fails, contact your SAKAI Dealer
immediately for appropriate inspection, maintenance, or repair.
NOTE: Refer to “Emergency traveling” on page 50 when it is necessary to move the machine
urgently.
*
Only AUTO SPEED mode, see 2. 3. 6 AUTO SPEED.
Error code
Fun ction / Compomet
Error
Engine stop
E01
Potentio meter
Out voltage to machine controller is
grounded
Yes
E02
Potentio meter
Output voltage to machine controller is
power supply voltage
Yes
E03
Forward switch / F-N-R lever
Short circuit to machine controller
Yes
E04
Forward switch / F-N-R lever
Broken wire
Yes
E05
Reverse switch / F-N-R lever
Short circuit to machine controller
Yes
E06
Reverse switch / F-N-R lever
Broken wire
Yes
E11
Speed sensor
Broken wire
Yes(
*
)
E15(Lo) Rolling surface temperature sensor (OPT)
Broken wire or low temperature
No
E21
Vibration selector switch
Broken wire / Short circuit to machine
controller
No
E22
IPF selector switch
Broken wire / Short circuit to machine
controller
No
E31
Current control /
Propel pump solenoid for forward
Current outside the nominal range
Yes
E32
Current control /
Propel pump solenoid for reverse
Current outside the nominal range
Yes
E33
Current control /
Vibration pump solendid for left
Current outside the nominal range
No
E34
Current control /
Vibration pump solendid for right
Current outside the nominal range
No
E41
CAN BUS / ECU
Signal defect to machine controller
Yes(
*
)
E42
Traveling controller
Signal defect to machine controller
Yes
E43
Exact meter
Signal defect to exact meter
Yes
E44
Working controller
Signal defect to machine controller
Yes
E45
Working controller
Parameter error
Yes
E61,E65
Potentio meter
Potentio error at the Neutral position
Yes
E62,E66
Potentio meter
Potentio error at the Forward or Reverse
position
Yes
E63,E67
Potentio meter
Potentio error at the motionless F-N-R
lever
Yes
E64,E68
Potentio meter
Potentio error at the motion F-N-R lever
Yes
Содержание SW880-1
Страница 4: ......
Страница 82: ...3 PERIODIC MAINTENANCE 78 3 3 Periodic Maintenance Points...
Страница 101: ...3 PERIODIC MAINTENANCE 97...
Страница 104: ...3 PERIODIC MAINTENANCE 100...
Страница 110: ......