2. OPERATION
– 32 –
– 33 –
Vibration frequency selector switch
2500 position : Vibration can be set at 2500 vpm in the
low or high amplitude position.
3000 position : Vibration can be set at 3000 vpm in the
low or high amplitude position.
4000 position : Vibration can be set at 4000 vpm in the
low amplitude position only.
Vibration will automatically be limited
to 3000 vpm when high amplitude is
selected, regardless of the frequency
selection. This machine can not operate
at 4000 vpm in high amplitude.
NOTE: Selection is applied only when the F-N-R lever is in the neutral position.
Vibration switch
The vibration switch is integrated on the F-N-R lever.
The green button toggles vibration “ on ” and “ off ”.
When the green button is depressed the first time,
vibration will turn on. When the green button is depressed
a second time, vibration will shut off. The button must be
depressed and held for one second in
order to engage. It works only when “ ” is selected on
the “ Vibration mode ” selector switch.
NOTE: For vibratory compaction, the “ Engine Speed ” selection switch must be in the FULL
position.
The vibrator indicator lamp stays lit at all times when the machine is running in vibratory
mode.