3. PERIODIC MAINTENANCE
– 94 –
⑪
Air cleaner
When the red float of the dust indicator reaches the service level (a mark on the indicator),
change the element as described below.
1) Release the service door clips to remove the primary element from the main filter housing.
2) Primary element:
Grasp the handle in the center of the element and pull the filter element outward.
Clean the inside of the housing with a damp rag to remove all loose dirt and dust.
3) Secondary Element
CAUTION
• Take caution when removing the secondary element. Any loose debris can fall
into the air intake plumbing leading directly to the engine. Clean the area around
the secondary filter element and replace the secondary promptly to avoid engine
contamination ingestion.
• Do not attempt to clean the filter element. Cleaning filter elements by impact or
compressed air voids the warranty and can degrade or damage the filter media
leading to malfunction.
NOTE: The secondary element should be changed every third time that the primary element
is changed. If the primary element has been breached then an inspection of the
secondary filter must be performed and changed if necessary.
The secondary element is removed by pulling on the plastic ring tabs on the inside
face of the filter element.