-60-
11 Alarm function
11.1 Manual fortify
11.1.1 single point arm
Operation: SET + x + CAM.
(
x
:
probe number
)
For example: number 3 area arm
Operation: SET +3 + CAM
11.1.2 single point disarm
Operation: CLEAR + x + CAM
。(
x
:
Probe number
)
For example: number 3 area disarm
Operation: CLEAR + 3 + CAM
11.1.3 area arm
Operation: SET + x + ALARM
。(
x
:
area number
)
For example: number 3 area arm
Operation: SET + 3 + ALARM
11.1.4area disarm
Operation: CLEAR + x + ALARM
。(
x
:
area number
)
For example: number 3 area disarm
Operation: CLEAR + 3 + ALARM
11.1.5 all arm
Operation: SET + 0 + ALARM
11.1.6 all disarm
Operation: CLEAR + 0 + ALARM
Note: the alarm messages won
’
t be sent to system if the armless area alarmed.
11.2 Manual alarm ACK
In the manual alarm ACK mode, appoint keyboard ACK the alarm message on the appoint monitor. The
appoint monitor means switch the present monitor of the ACK keyboard to the alarm monitor.
11.2.1 Manual ACK present single alarm
Operation: press ALARM
11.2.2 Manual ACK all the alarm on the monitor
Operation: x + ALARM
。(
x
:
monitor number
)
11.2.3 Manual ACK all the alarm in the fortify area
Operation:
(
x + 64
)
+ ALARM
。(
x
:
area number
)
11.2.4 Manual ACK all the alarm
Operation: 255 + ALARM
12 power down protection
12.1 Modify the detail of the main menu, then turn the power down, the program data
will be protected
.
12.2 After manual arm/ disarm and alarm were occur, the records in the system are correct.