Description
Location
Event
Configures the next transition area of the selected area to take all keys off-air
with the next transition.
1.
Click the ME button and select the area that you want to perform the
event on.
2.
Click the Action button and select Trans Clear.
Switcher > Transition >
ME Trans Action
Trans Clear
Select the elements to be included in the next transition of the selected area.
1.
Click the ME button and select the area that you want to perform the
event on.
2.
Click the Elements button and select background and/or the keys that
you want to include in the next transition.
Switcher > Transition >
ME Trans Elements
Trans Elements
Turn the transition limit feature on or off for the selected area.
1.
Click the ME button and select the area that you want to perform the
event on.
2.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
3.
Click the Value button and select whether trans limit is on (On) or not
(Off).
Switcher > Transition >
ME Trans Limit
Trans Limit — On/Off
Resets the transition limit point of the selected area.
1.
Click the ME button and select the area that you want to perform the
event on.
2.
Click the Action button and select Reset Limit.
Switcher > Transition >
ME Trans Action
Trans Limit — Reset
Sets the transition limit point of the selected area. You must select the point
in the transition that you want to place the limit before running this event.
1.
Click the ME button and select the area that you want to perform the
event on.
2.
Click the Action button and select Set Limit.
Switcher > Transition >
ME Trans Action
Trans Limit — Set
Select the limit point for the trans limit of the selected area.
1.
Click the ME button and select the area that you want to perform the
event on.
2.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
3.
Enter the point in the transition that you want to place the trans limit in
the Value (%) field.
Switcher > Transition >
ME Trans Limit Value
Trans Limit — Value
Select whether the wipe reverses direction for every second transition of the
selected ME.
1.
Click the ME button for the ME that you want to perform the event on.
2.
Click the Pattern button and select Wipe.
3.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
4.
Click the Parameter button and select Flip-Flip.
5.
Click the Value button and select whether Flip-Flop is on (On) or off (Off).
Switcher > Transition >
Wipe Direction
Wipe Direction
(Flip-Flop)
Ultra User Manual (v6.6) — Custom Control Events • 185