Description
Location
Event
Select the position for the bottom edge of the box mask on the selected key
for the selected ME.
1.
Click the ME button for the ME that you want to perform the event on.
2.
Click the Keyer button for the key you want to perform the event on.
3.
Click the Parameter button and select Bottom Edge.
4.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
5.
Enter a new position in the Value (%) field.
Switcher > Keyer > Box
Mask Param
Mask (Box) — Bottom
Edge Position
Select the amount of softness to apply to the edges of the box mask on the
selected key for the selected ME.
1.
Click the ME button for the ME that you want to perform the event on.
2.
Click the Keyer button for the key you want to perform the event on.
3.
Click the Parameter button and select Edge Softness.
4.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
5.
Enter a new softness amount in the Value (%) field.
Switcher > Keyer > Box
Mask Param
Mask (Box) — Edge
Softness
Select the position for the left edge of the box mask on the selected key for
the selected ME.
1.
Click the ME button for the ME that you want to perform the event on.
2.
Click the Keyer button for the key you want to perform the event on.
3.
Click the Parameter button and select Left Edge.
4.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
5.
Enter a new position in the Value (%) field.
Switcher > Keyer > Box
Mask Param
Mask (Box) — Left
Edge Position
Select the position for the right edge of the box mask on the selected key for
the selected ME.
1.
Click the ME button for the ME that you want to perform the event on.
2.
Click the Keyer button for the key you want to perform the event on.
3.
Click the Parameter button and select Right Edge.
4.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
5.
Enter a new position in the Value (%) field.
Switcher > Keyer > Box
Mask Param
Mask (Box) — Right
Edge Position
Select the size of the box mask on the selected key for the selected ME.
1.
Click the ME button for the ME that you want to perform the event on.
2.
Click the Keyer button for the key you want to perform the event on.
3.
Click the Parameter button and select Size.
4.
Click the Change Type button and select whether you want to set
(Absolute) or reset (Reset) the parameter. Some selections will not be
available when you reset the parameter.
5.
Enter a new size in the Value (%) field.
Switcher > Keyer > Box
Mask Param
Mask (Box) — Size
154 • Custom Control Events — Ultra User Manual (v6.6)