Live Edit Decision Lists
(LiveEDL)
Edit Decision Lists are files used by non-linear
editing (NLE) suites to aid in post-production.
Your switcher can capture EDL data in a file that
you load into your NLE suite.
LiveEDL Setup
You can configure your switcher to trigger
multiple GPI outputs at the start, end, or both,
of an EDL data capture to trigger video servers
that are recording the feeds coming into the
switcher. The EDL data from the switcher can
then be paired with the feeds from the video
servers, using the timecode data, in the NLE
suite to edit or re-cut the show.
Important:
A control panel is required to configure
this feature. If you do not have access to a physical
control panel, the SoftPanel can be used.
You can configure your switcher to trigger
multiple GPI outputs at the start, end, or both,
of an EDL data capture to trigger video servers
that are recording the feeds coming into the
switcher. The EDL data from the switcher can
then be paired with the feeds from the video
servers, using the timecode data, in the NLE
suite to edit or re-cut the show.
You can also set a pre-delay for each GPI output.
EDL data capture does not begin until the
highest pre-delay has passed. This is useful when
the switcher needs to wait for external
equipment to become ready. The example below
shows the effects of various triggering and
pre-delay settings.
To Set the LiveEDL Behavior
Important:
A control panel is required to perform
this procedure. If you do not have access to a physical
control panel, the SoftPanel can be used. The position
of items on the menus on the SoftPanel may not
match those of a physical panel.
1.
Press
MENU
>
System
>
NEXT
>
NEXT
>
NEXT
>
LivEDL Config
.
2.
Use the
GPO
knob to select the GPI output
that is connected to your video server.
The GPI must be configured as a GPI output
before it can be selected.
3.
Use the
Triggr
knob to select when the GPI
output is triggered.
•
Off
— GPI is not triggered
•
Start
— GPI output is triggered at the
beginning of the EDL capture
•
Stop
— GPI output is triggered at the end
of the EDL capture
•
Both
— GPI output is triggered at the
beginning and end of the EDL capture
If Start or Both is selected, you must set the
pre-delay for the GPI.
4.
Use the
PreDly
knob to select the pre-delay
interval (in frames) that the switcher waits
after the GPI output is triggered before
starting to capture EDL data.
Timecode Setup
The switcher uses timecode data to mark the
EDL file so that it can be used in the non-linear
editing suite along with the feeds from the video
servers. The timecode data can be either from
an external timecode generator, or internally
generated. An offset can be applied to both
timecode sources.
For an external timecode, an LTC generator
must be connected to the LTC port on the back
of the frame.
To Confirm External LTC Signal
If you have an external linear timecode
generator connected to the switcher, you can
confirm that the switcher is receiving timecode
data.
Important:
A control panel is required to perform
this procedure. If you do not have access to a physical
control panel, the SoftPanel can be used. The position
of items on the menus on the SoftPanel may not
match those of a physical panel.
1.
Click
Navigation Menu
>
Status
2.
Confirm that the information shown in the
Timecode
field matches the timecode from
the timecode generator.
If required, an offset can be applied to the
incoming timecode data.
To Set Up Communications with a TSC-9902
Important:
A control panel is required to perform
this procedure. If you do not have access to a physical
control panel, the SoftPanel can be used. The position
of items on the menus on the SoftPanel may not
match those of a physical panel.
114 • Live Edit Decision Lists (LiveEDL) — Ultra User Manual (v6.6)
Содержание Carbonite Ultra Series
Страница 1: ...Ultra User Manual v6 6...