237
Appendices
Address(H)
Size(H)
Data(H)
Parameter
Default Value (H)
Description
40 03 00
00 00 02
00 – 7F
EFX TYPE
00 00
00: Thru
40 03 01#
40 03 03
00 00 01
00 – 7F
EFX PARAMETER 1
40 03 04
00 00 01
00 – 7F
EFX PARAMETER 2
40 03 05
00 00 01
00 – 7F
EFX PARAMETER 3
40 03 06
00 00 01
00 – 7F
EFX PARAMETER 4
40 03 07
00 00 01
00 – 7F
EFX PARAMETER 5
40 03 08
00 00 01
00 – 7F
EFX PARAMETER 6
40 03 09
00 00 01
00 – 7F
EFX PARAMETER 7
40 03 0A
00 00 01
00 – 7F
EFX PARAMETER 8
40 03 0B
00 00 01
00 – 7F
EFX PARAMETER 9
40 03 0C
00 00 01
00 – 7F
EFX PARAMETER 10
40 03 0D
00 00 01
00 – 7F
EFX PARAMETER 11
40 03 0E
00 00 01
00 – 7F
EFX PARAMETER 12
40 03 0F
00 00 01
00 – 7F
EFX PARAMETER 13
40 03 10
00 00 01
00 – 7F
EFX PARAMETER 14
40 03 11
00 00 01
00 – 7F
EFX PARAMETER 15
40 03 12
00 00 01
00 – 7F
EFX PARAMETER 16
40 03 13
00 00 01
00 – 7F
EFX PARAMETER 17
40 03 14
00 00 01
00 – 7F
EFX PARAMETER 18
40 03 15
00 00 01
00 – 7F
EFX PARAMETER 19
40 03 16
00 00 01
00 – 7F
EFX PARAMETER 20
*
Regarding EFX TYPE and EFX PARAMETER, please refer to page 91, 216
Address(H)
Size(H)
Data(H)
Parameter
Description
Default Value (H)
Description
40 03 17
00 00 01
00 – 7F
EFX SEND LEVEL TO REVERB
0-127
28
40
40 03 18
00 00 01
00 – 7F
EFX SEND LEVEL TO CHORUS
0-127
00
0
40 03 19
00 00 01
00 – 7F
EFX SEND LEVEL TO DELAY
0-127
00
0
40 03 1B
00 00 01
00 – 7F
EFX CONTROL SOURCE1
Off, CC1-95, CAf, Bend
00
Off
40 03 1C
00 00 01
00 – 7F
EFX CONTROL DEPTH1
-100 – 0 – +100 [%]
40
0 (%)
40 03 1D
00 00 01
00 – 7F
EFX CONTROL SOURCE2
Off, CC1 – 95, CAf, Bend
00
Off
40 03 1E
00 00 01
00 – 7F
EFX CONTROL DEPTH2
-100 – 0 – +100 [%]
40
0 (%)
40 03 1F
00 00 01
00 – 7F
EFX SEND EQ SWITCH
OFF/ON
01
ON
*
EFX TYPE is a macro parameter which sets various Insertion Effect parameters as a group. When you use EFX TYPE to select an Insertion Effect type, each effect parameter will be set to the
most suitable value.
❍
Patch Part parameters
The SC-8850 has 16 Parts in Group A, Group B, Group C, and Group D respectively. Parameters that can be set individually for each Part are called Patch Part parameters. If you specify a part in
Group A, specify the address 40 ** ** using the block number to the corresponding part from PORT A (normally MIDI IN 1). If you specify a part in Group B, specify the address 40 ** ** using the
block number to the corresponding part from PORT B (normally MIDI IN 2).
If you use Exclusive messages to set Patch Part parameters, specify the address by Block number rather than Part Number (normally the same number as the MIDI channel). The Block number can
be specified as one of 16 blocks, from 0(H) to F(H).
The relation between Part number and Block number is as follows.
x...BLOCK NUMBER (0 – F),
Part 1
(default MIDIch = 1)
x=1
Part 2
(default MIDIch = 2)
x=2
:
:
:
Part 9
(default MIDIch = 9)
x=9
Part10
(default MIDIch =10)
x=0
Part11
(default MIDIch =11)
x=A
Part12
(default MIDIch =12)
x=B
:
:
:
Part16
(default MIDIch =16)
x=F
n... MIDI channel number (0 – F) of the BLOCK.
In the following map, the control numbers of the control changes are indicated as CC#.
Address(H)
Size(H)
Data(H)
Parameter
Description
Default Value (H)
Description
40 1x 00
00 00 02
00 – 7F
TONE NUMBER
CC#00 VALUE 0 – 127
00
0
40 1x 01#
00 – 7F
P.C. VALUE 1 – 128
00
1
40 1x 02
00 00 01
00 – 10
Rx. CHANNEL
1 – 16, OFF
Same as the Part Number
40 1x 03
00 00 01
00 – 01
Rx. PITCH BEND
OFF/ON
01
ON
40 1x 04
00 00 01
00 – 01
Rx. CH PRESSURE(CAf)
OFF/ON
01
ON
40 1x 05
00 00 01
00 – 01
Rx. PROGRAM CHANGE
OFF/ON
01
ON
40 1x 06
00 00 01
00 – 01
Rx. CONTROL CHANGE
OFF/ON
01
ON
40 1x 07
00 00 01
00 – 01
Rx. POLY PRESSURE(PAf)
OFF/ON
01
ON
40 1x 08
00 00 01
00 – 01
Rx. NOTE MESSAGE
OFF/ON
01
ON
40 1x 09
00 00 01
00 – 01
Rx. RPN
OFF/ON
01
ON
40 1x 0A
00 00 01
00 – 01
Rx. NRPN
OFF/ON
00 (01*)
OFF (ON*)
*
When “GM1 System On” and “GM2 System On” are received, Rx. NRPN will be set OFF. When “GS Reset” is received, it will be set ON.
Содержание Sound Canvas SC-8850
Страница 256: ...SC 8850 Owner s Manual 01891545 00 7 A3 31N...