208
Rockwell Automation Publication 2080-UM002N-EN-E - November 2022
Chapter 10 Use the High-Speed Counter and Programmable Limit Switch
HSC Mode 9 – Quadrature X4 Counter with External Reset and Hold
This parameter is the initial HSC Accumulator value that need to be set when starting the HSC.
This parameter is updated by the HSC sub-system automatically when the HSC is in Counting
mode, reflecting the actual HSC accumulator value.
The HSCAPP.HPSetting is the upper setpoint (in counts) that defines when the HSC sub-system
generates an interrupt.
The data loaded into the high preset must be less than to the data resident in the overflow
(HSCAPP.OFSetting) parameter or an HSC error is generated.
The HSCAPP.LPSetting is the lower setpoint (in counts) that defines when the HSC sub-system
generates an interrupt.
The data loaded into the low preset must be:
1. Less than or equal to 0 for HSC Mode (HSCAPP.HSCMode) parameter values 0 and 1 or an
HSC error is generated.
2. Greater than or equal to the data resident in the underflow (HSCAPP.UFSetting)
parameter for all HSC Mode (HSCAPP.HSCMode) or an HSC error is generated.
If the underflow and low preset values are negative numbers, the low preset must be a number
with a smaller absolute value.
Table 52 - HSC Mode 9 Examples
Embedded Input
0(HSC0) (A))
Embedded Input
1(HSC0) (B)
Embedded Input
2(HSC0) (Reset)
Embedded Input
3(HSC0) (Hold)
Value of CE Bit
Accumulator and Counter Action
OFF
X
-
TRUE
Count Up Acc. Value
ON
X
-
TRUE
Count Down Acc. Value
OFF
X
-
TRUE
Count Down Acc. Value
ON
X
-
TRUE
Count Up Acc. Value
OFF
X
-
TRUE
Count Down Acc. Value
ON
X
-
TRUE
Count Up Acc. Value
OFF
X
-
TRUE
Count Up Acc. Value
ON
X
-
TRUE
Count Down Acc. Value
OFF or ON
OFF or ON
OFF
X
X
Hold Acc. Value
OFF
OFF
ON
X
X
Reset Acc. to Zero
X
X
OFF
ON
X
Hold Acc. Value
X
X
OFF
X
FALSE
Hold Acc. Value
Accumulator (HSCAPP. Accumulator)
Description
Data Format
User Program Access
HSCAPP.Accumulator
long word (32-bit INT)
read/write
High Preset (HSCAPP.HPSetting)
Description
Data Format
User Program Access
HSCAPP.HPSetting
long word (32-bit INT)
read/write
Low Preset (HSCAPP.LPSetting)
Description
Data Format
User Program Access
HSCAPP.LPSetting
long word (32-bit INT)
read/write
Overflow Setting (HSCAPP.OFSetting)
Description
Data Format
Type
User Program Access
HSCAPP.OFSetting
long word (32-bit INT)
control
read/write
Содержание 2080-L50E-24AWB
Страница 14: ...14 Rockwell Automation Publication 2080 UM002N EN E November 2022 Notes ...
Страница 54: ...54 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 4 Wire Your Controller Notes ...
Страница 128: ...128 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 7 Program Execution in Micro800 Notes ...
Страница 156: ...156 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 8 EtherNet IP Network Notes ...
Страница 198: ...198 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 9 Motion Control Notes ...
Страница 232: ...232 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 11 Controller Security Notes ...
Страница 260: ...260 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 12 Using microSD Cards Notes ...
Страница 266: ...266 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix A Modbus Mapping for Micro800 Notes ...
Страница 275: ...Rockwell Automation Publication 2080 UM002N EN E November 2022 275 Appendix B Quickstarts 10 Click Finish to complete ...
Страница 332: ...332 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix E PID Function Blocks Notes ...
Страница 352: ...352 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix G Connect to Networks using DF1 Notes ...
Страница 388: ...388 Rockwell Automation Publication 2080 UM002N EN E November 2022 Index Notes ...