Chapter 9 Motion Control
When a motion control function block ends with an error, and the axis is in ErrorStop state, in
most cases, MC_Reset function block (or, MC_Power Off/On and MC_Reset) can be used to have
the axis to be recovered. With this, the axis can get back to normal motion operation without
stopping the controller operation.
Major Fault Handling
In case the controller encounters issues where recovery is not possible through the Stop,
Reset, or Power function blocks, controller operation will be stopped and a major fault will be
reported.
defines the motion-related major fault codes for Micro830, Micro850, and
Micro870 controllers.
11
MC_FB_ERR_HARD_LIMIT
This function block is aborted as the Hard Limit switch
active state has been detected during axis movement, or
aborted as the Hard Limit switch active state has been
detected before axis movement starts.
Move the axis away from the hard limit switch in the
opposite direction.
The axis is not operational due to hard limit error detected.
Reset the state of the axis using the MC_Reset function
block, and then move the axis away from the hard limit
switch in the opposite direction.
12
MC_FB_ERR_LOG_LIMIT
This function block cannot execute as it will end up moving
beyond the PTO Accumulator logic limit, or the function
block is aborted as the PTO Accumulator logic limit has been
reached.
Check the velocity or target position settings for the
function block. Or, use MC_SetPosition function block to
adjust the axis coordinate system.
The axis is not operational due to PTO Accumulator logic
limit error detected, or due to expected PTO accumulator
logic limit error in a function block.
Reset the state of the axis using the MC_Reset function
block.
Check the velocity or target position settings for the
function block. Or, use MC_SetPosition function block to
adjust the axis coordinate system.
13
MC_FB_ERR_ENGINE
A motion engine execution error is detected during the
execution of this function block.
Cycle power to the entire motion setup, including controller,
drives and actuators, and then download the User
Application again.
If the fault is persistent, call Tech support.
The axis is not operational due to a motion engine execution
error.
Cycle power to the entire motion setup, including controller,
drives and actuators, and then download the User
Application again.
If the fault is persistent, contact your local Rockwell
Automation technical support representative. For contact
information, see:
16
MC_FB_ERR_NOT_HOMED
The Function Block cannot execute because the axis needs
to be homed first.
Execute homing against the axis using MC_Home Function
Block.
The axis is not operational because the axis is not homed.
Reset the state of the axis using the MC_Reset Function
Block.
128
MC_FB_PARAM_MODIFIED
Warning
: The requested motion parameter for the axis has
been adjusted.
The function block executes successfully.
Motion internal Fault, Error ID = 0x80.
Contact your local Rockwell Automation technical support
representative. For contact information, see:
(1) You can view axis status through the Axis Monitor feature of the Connected Components Workbench software.
Table 27 - Motion Function Block and Axis Status Error ID (Continued)
Error ID
Error ID MACRO
Error Description for Function Block
Error Description for Axis Status
(1)
Содержание 2080-L50E-24AWB
Страница 14: ...14 Rockwell Automation Publication 2080 UM002N EN E November 2022 Notes ...
Страница 54: ...54 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 4 Wire Your Controller Notes ...
Страница 128: ...128 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 7 Program Execution in Micro800 Notes ...
Страница 156: ...156 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 8 EtherNet IP Network Notes ...
Страница 198: ...198 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 9 Motion Control Notes ...
Страница 232: ...232 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 11 Controller Security Notes ...
Страница 260: ...260 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 12 Using microSD Cards Notes ...
Страница 266: ...266 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix A Modbus Mapping for Micro800 Notes ...
Страница 275: ...Rockwell Automation Publication 2080 UM002N EN E November 2022 275 Appendix B Quickstarts 10 Click Finish to complete ...
Страница 332: ...332 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix E PID Function Blocks Notes ...
Страница 352: ...352 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix G Connect to Networks using DF1 Notes ...
Страница 388: ...388 Rockwell Automation Publication 2080 UM002N EN E November 2022 Index Notes ...