194
Rockwell Automation Publication 2080-UM002N-EN-E - November 2022
Chapter 9 Motion Control
6. Move to the configured home position. The mechanical home position recorded during
moving back sequence, plus the home offset configured for the axis through the
Connected Components Workbench software.
Scenario 3: Moving part on Lower Limit or Home switch before homing starts
The homing motion sequence for this scenario is as follows:
1. Moving part moves to its right side (in positive direction) in creep velocity to detect
Home switch On->Off edge;
2. Once Home Abs switch On->Off is detected, start to detect first Ref Pulse signal;
3. Once the first Ref Pulse signal comes, record the position as mechanical home position,
and decelerate to stop;
4. Move to the configured home position. The mechanical home position recorded during
moving right sequence, plus the home offset configured for the axis in the Connected
Components Workbench software.
Scenario 4: Moving part at left (negative) side of Lower Limit switch before homing starts
In this case, the homing motion fails and moves continuously to the left until drive or moving
part fails to move. User needs to make sure the moving part is at the proper location before
homing starts.
MC_HOME_REF_PULSE
For Homing against Lower Limit switch, one positive home offset can be configured; for
Homing against Upper Limit switch, one negative home offset can be configured.
MC_HOME_REF_PULSE (3) homing procedure performs a homing operation against Limit
switch, plus fine Ref Pulse signal. The actual motion sequence is dependent on the limit switch
configuration, and the actual status for the switches before homing starts—that is, when the
MC_Home function block is issued.
Scenario 1: Moving part at right (positive) side of Lower Limit switch before homing starts
The homing motion sequence for this scenario is as follows:
1. Moving part moves to its left side (in negative direction);
2. When Lower Limit switch is detected, the moving part decelerates to stop, or stops
immediately, according to Limit Switch Hard Stop configuration;
3. Moving part moves back (in positive direction) in creep velocity to detect Lower Limit
switch On->Off edge;
4. Once Lower Limit switch On->Off edge is detected, start to detect first Ref Pulse signal;
5. Once the first Ref Pulse signal comes, record the position as the mechanical home
position, and decelerate to stop;
6. Move to the configured home position. The mechanical home position recorded during
moving back sequence, plus the home offset configured for the axis through the
Connected Components Workbench software.
IMPORTANT
In this case, if Lower limit switch is not configured, or not wired, the
homing motion will fail and moves continuously to the left until the drive
or moving part fails to move.
IMPORTANT
If Lower Limit switch or Ref Pulse is not configured as Enabled,
MC_HOME_REF_PULSE (3) homing fails (ErrorID: MC_FB_ERR_PARAM).
Содержание 2080-L50E-24AWB
Страница 14: ...14 Rockwell Automation Publication 2080 UM002N EN E November 2022 Notes ...
Страница 54: ...54 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 4 Wire Your Controller Notes ...
Страница 128: ...128 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 7 Program Execution in Micro800 Notes ...
Страница 156: ...156 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 8 EtherNet IP Network Notes ...
Страница 198: ...198 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 9 Motion Control Notes ...
Страница 232: ...232 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 11 Controller Security Notes ...
Страница 260: ...260 Rockwell Automation Publication 2080 UM002N EN E November 2022 Chapter 12 Using microSD Cards Notes ...
Страница 266: ...266 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix A Modbus Mapping for Micro800 Notes ...
Страница 275: ...Rockwell Automation Publication 2080 UM002N EN E November 2022 275 Appendix B Quickstarts 10 Click Finish to complete ...
Страница 332: ...332 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix E PID Function Blocks Notes ...
Страница 352: ...352 Rockwell Automation Publication 2080 UM002N EN E November 2022 Appendix G Connect to Networks using DF1 Notes ...
Страница 388: ...388 Rockwell Automation Publication 2080 UM002N EN E November 2022 Index Notes ...