![ROBOTIQ RWC-CAM-001 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/robotiq/rwc-cam-001/rwc-cam-001_instruction-manual_1471345018.webp)
3.3. Environmental and Operating Conditions
The Wrist Camera is designed for industrial applications. Always respect the following specified operating environmental conditions:
CONDITION
VALUE
Minimum storage
-30°C [-22°F]
Maximum storage
70°C [158°F]
Minimum operating
temperature
0°C [32°F]
Maximum operating
temperature
50°C [122°F]
Humidity (non-condensing)
Non-condensing.
IP Rating
IP67
Others
Lenses must be free from dust, soot and water.
Environment must be free from powerful electromagnetic
interference.
Environment must be free from corrosive or explosive liquids or
gases.
Table 3-2: Environmental and operating conditions for the Wrist Camera.
3.4. Mechanical Installation
3.4.1. Mounting the Wrist Camera with an end-effector on Universal Robots
1. Place the Wrist Camera(RWC-CAM-001) on the robot arm. Align the wrist camera's dowel pin with tool flange.
2. Place the tool plate (RWC-TOOL-062) on the Wrist Camera. Align the tool plate dowel pin with theWrist Camera.
3. Mount end-effector on robot arm, using M6 screws that pass through the tool plate and the Wrist Camera.
4. Attach cable along robot arm.
18
Содержание RWC-CAM-001
Страница 3: ...10 1 Declarationof Incorporation 132 10 2 ngressProtectionCertificate 133 11 Contact 134 3...
Страница 53: ...Wrist Camera Instruction Manual Summary of Camera Settings 53...
Страница 132: ...1 0 Harmonized Standards Declarationsand Certificates 1 0 1 Declaration of Incorporation Wrist Camera Instruction Manual...