Chapter 2-12
Robomow City 120
2.11 Completing and Testing the Setup
Once the Perimeter Wire loop is completed and pegged to the
ground, you complete the setup by attaching the beginning and
end of the Perimeter Wire to the Perimeter Switch.
P
At the end of the Perimeter Wire’s loop, you have now two
wires: one at the beginning and one at the end of the loop.
Lay the two loose wires in the direction of the Perimeter
Switch location and peg them to the ground using a single peg
for both.
2.12 At the Perimeter Switch’s location:
P
Trim the ends of the loose wire (the one without the
connector) to equal lengths and twist them together.
P
Strip 5 mm (0.2 inches) of insulation from the wire that is not
connected to the plot connector.
P
Insert this wire’s end into the free hole in the connector and
tighten the screws.
P
Plug the perimeter wire connector into the Perimeter Switch
(see figure)
P
Hold the Perimeter Switch and squeeze its side tabs to remove it from
the back cover.
P
Connect the power supply plug to the Perimeter Switch board.
Replace the cover.
P
Connect the power supply to a regular household receptacle
230/120 Volts AC.
c
IMPORTANT
c
The Power Supply is for indoor use only.
Choose a sheltered, dry, well ventilated location that is NOT exposed to
direct sunlight, water or rain.
Indoor Use Only
Completing Perimeter Wire
at Perimeter Switch