Engineer Programming
Page 112
Quick Keys
Parameter
Battery Test
A pulsed programmable output will follow the battery test only once a
day at 9:00 AM. The pulse interval is ten seconds. This parameter is
usually used to perform an overload test on the system by using an
external device.
Bell Burglary
Activates the programmable output after any bell burglary alarm in any
partition in the system.
Scheduler
The programmable output will follow the predefined time
programming that is defined in the scheduler of the weekly programs
for programmable output activation. For additional details, refer to the
LightSYS User's Manual
.
Switched Aux
Activates the programmable output when a fire zone is activated (for
fire detection) according to the time defined in double verification of
fire alarms, page 68.
This programmable output will not have the option to choose pulse or
latch in the Programmable output: Code. The pulse time is defined in
switched auxiliary break, page 62.
GSM Error
Relates to GSM/GPRS module. Activates the programmable output in
the following cases:
There is no SIM card in the GSM/GPRS BUS Module or SIM is
faulty
GSM RSSI signal level is low
GSM network fault
Bell Test
Activates the output when the “Bell Test” option is selected and
deactivates when the “Bell Test” option is finished.