Engineer Programming
Page
75
Quick Keys
Parameter
Default
Range
Configuration Software
(U/D) Enable
Yes
Yes/No
YES
: Enables communication between the alarm company and the
LightSYS main panel using the configuration software. This enables
modifying an installation's configuration, obtaining status information,
and issuing main panel commands, all from a remote location.
NO
: Disables communication, as detailed above.
System: Controls: EN 50131
Quick Keys
Parameter
Default
Range
EN 50131
This section refers to controls that apply to EN 50131 approvals.
Authorize Engineer
No
Yes/No
This option limits the engineer and sub-engineer authorization to access
the programming menu.
YES
: A grand master code is required to authorize the engineer to enter
the programming mode for one hour.
NO
: The engineer does not need an authorization code.
Override Fault
Yes
Yes/No
Specifies if the system/partition can be set when there is a fault in the
system.
YES
: The system will set even if there is a fault in the system.
NO
: When the user starts the arming process and there is a system-fault,
the user must confirm that he is aware of all faults before continuing
with the arming process. The user needs to scroll the list of faults. At the
end of the list the following question will appear: « Override Fault? »
Using the
key he needs to toggle the option to Y and press
.
Restore Alarm
No
Yes/No
YES
: The user must confirm that he is aware that alarm occurred in the
system before rearming the system. The system/partition will be in “Not
Ready” status until it confirms the alarm. The user needs to confirm the
alarm by going to View > Alarm Memory
NO
: The user does not need to confirm the alarm before rearming the
system.