Engineer Programming
Page 168
Quick Keys
Parameter
Default
Range
to toggle and choose the sounder option:
NONE
SIRN (Prosound A)
SIRN2 (ProSound B)
LUM8 (Lumin 8, See page 46)
4.
Press
. The partition display appears:
P=1234 S=1
Y...
5.
Use the
or
keys and the
key to assign that
partition to the sounder.
6.
Press
. The following display appears.:
SOUNDER= 1
SOUND? Y
7.
Use the
key to toggle
Y
Yes or
N
No to activate or
deactivate the sound.
8.
Press
. The following display appears.:
SOUNDER= 1
SQUAWK SOUND? Y
9.
Use the
key to toggle
Y
Yes or
N
No. If yes, the sounder
will sound one squawk to indicate the set status.
10.
Press
. The following display appears.:
SOUNDER= 1
SQUAWK STROBE? Y
11.
Use the
key to toggle
Y
Yes or
N
No. If yes, the sounder
will flash to indicate the set status.
12.
Repeat above steps for other sounders if needed.
BUS Zones
Up to 32 addressable bus detectors can be assigned to the LightSYS. Bus
detectors can be wired to the main bus or to a Bus Zone
Expander (BZE).
For full installation instructions refer to the instructions supplied with
each bus detector.
To specify and configure a bus zone detector
1.
Through the menu selection, the following display appears:
BUS ZONE: (01)