Engineer Programming
Page
87
8.
Press
to confirm and proceed to the zone type category, displayed as follows:
Z=01 TYPE:
01)EX/EN1
(and subsequently sound (page 94), termination (page 95) and loop response (page 95).
Zones: Parameters: By Category
Use this option to modify settings of a specific parameters to all zones.
Quick Keys
Parameter
Default
Range
Label
The label identifies the zone in the system. Up to 16 characters, as per
the procedure
described on page 52.
Partition
Select the partition (1-4) assignment for each zone
.
Group
Select the groups for each zone using the using the
key.
Type
The Zone Type menu
contains
parameters
that
enable you to program
the zone type for any zone.
Setting the zone type is partly determined by
the arming levels. Three arming levels exist, as follows:
Unset:
The system reacts only to those zones defined as 24 HR, Fire,
Panic, and Fault.
Set:
The system reacts to all zones.
Part Set:
The system does not react to zones defined as internal (home).
This setting allows freedom of movement in those zones
Note:
Zones for home arming (PART SET) must be defined as Interior type
Available options:
06: IExit/Entry 1, 09: InEntry follower
07: IExit/Entry 2, 10: IIntruder
08: IExit(OP)/Entry, ,
Zone Type
Quick Keys
Parameter
Default
Range
ZZ
Not Used
Disables a zone. All unused zones should be given this designation
ZZ
Exit/Entry 1