Engineer Programming
Page
143
Quick Keys
Parameter
Default
Range
Random ARC Testing
No
Yes/No
Yes
: At power-up the panel will random set a test time between 00:00
and 23:59. Once the hour is set, this will be the fixed report hour of this
panel. The time can be viewed under the Periodic test timer fields
(
). The interval of sending the test will be as defined under the
Periodic Test timer
No
: The periodic test will be according to the time defined under the
ARC periodic timer (
).
Parameters
Allows to program parameters related to operation with the Alarm
Receiving Centre
ARC Retries
08
01–15
The number of times the LightSYS redials the ARC after failing to
establish communication.
Alarm Restore
Specifies under what conditions an Alarm Restoral is reported. This
option informs the ARC of a change in the specified condition(s) during
an alarm restore. These reports need a valid Report Code.
ON BTO
(Bell Time Out)
-
Reports the restoral after the audible
alarm times out.
FOLLOW ZONE
-
Reports the restoral when the zone in which the
alarm occurs
returns to its non-violated (secured) state.
AT UNSET
- Reports the restoral when the system (or the partition in
which the alarm occurs) is unset, even if the sounder has already timed
out.
ARC Timers
Allows to program timers related to operation with the alarm receiving
centre
Periodic Test
The Periodic Test enables you to set the time period that the system will
automatically establish communication to the alarm receiving centre in
order to check the connection. The periodic test involves sending the
account number and a valid test report code (Contact ID 602, SIA TX). Set
the test time and daily interval for Periodic Test Reporting.
Содержание LightSYS