Installing Bus Devices
Page
33
Setting Bus Accessory ID Numbers
For most devices, a DIP switch number must be set to identify its ID category number.
Devices are split into ‘Families’. Each ‘Family’ of devices has sequential identification
numbers which are set by the DIP switches. Before setting power on, define each module’s ID
number by setting the DIP switches as follows:
ID
DIP switches
ID
DIP switches
1
2
3
4
5
1
2
3
4
5
01
OFF
OFF OFF OFF OFF
17
OFF OFF OFF OFF ON
02
ON
OFF OFF OFF OFF
18
ON
OFF OFF OFF ON
03
OFF
ON
OFF OFF OFF
19
OFF ON
OFF OFF ON
04
ON
ON
OFF OFF OFF
20
ON
ON
OFF OFF ON
05
OFF
OFF ON
OFF OFF
21
OFF OFF ON
OFF ON
06
ON
OFF ON
OFF OFF
22
ON
OFF ON
OFF ON
07
OFF
ON
ON
OFF OFF
23
OFF ON
ON
OFF ON
08
ON
ON
ON
OFF OFF
24
ON
ON
ON
OFF ON
09
OFF
OFF OFF ON
OFF
25
OFF OFF OFF ON
ON
10
ON
OFF OFF ON
OFF
26
ON
OFF OFF ON
ON
11
OFF
ON
OFF ON
OFF
27
OFF ON
OFF ON
ON
12
ON
ON
OFF ON
OFF
28
ON
ON
OFF ON
ON
13
OFF
OFF ON
ON
OFF
29
OFF OFF ON
ON
ON
14
ON
OFF ON
ON
OFF
30
ON
OFF ON
ON
ON
15
OFF
ON
ON
ON
OFF
31
OFF ON
ON
ON
ON
16
ON
ON
ON
ON
OFF
32
ON
ON
ON
ON
ON
Notes:
Most accessories have four DIP switches, while bus detectors have five DIP switches
IDs 9–32 are only available for bus detectors.
If a DIP switch is changed on any device, it is necessary to shut down the device’s
power and then re-power it
.
The first module in each category is defined as ID= 1.
Families that have sequential ID numbers are:
Keypads (LCD, LCD with proximity and wireless keypad)
Zone expanders (8 zones expander, bus zone expander)
Outputs (4 relay output expander, 8 open collector output expander, 2 relay output
expander on 3A power supply, 2 relay output expander on Wireless zone expander,
X-10 Outputs)
Power supplies (3A switching mode power supply)
Bus zones WL zone expanders
Notes:
1.
The main unit can support a maximum load of 1.4 Amp. If more current
is
required, install additional power supply modules (3 Amp max.).
2.
On 3 Amp supervised power supplies and on the wireless expander, there are
two programmable outputs. These programmable outputs belong to the ‘Output’
family. These outputs have dedicated DIP switches that identify the OUTPUT ID.
Содержание LightSYS