Engineer Programming
Page 104
Bus Zone: WatchIN DT Grade 3
Quick Keys
Parameter
Default
Range
ZZ
LEDS
3 LEDS
Defines the LEDS operation mode.
OFF
- Disables the LEDS operation.
RED ONLY
- Only the Red LED will operate. This option is highly
recommended to avoid the possibility that an intruder will “Learn” the
detector behavior.
3 LEDS -
All 3 LEDs will operate..
ZZ
Detection Sensitivity
Normal
Defines the sensitivity of the detector (MW + PIR).
LOW
MEDIUM
NORMAL
ACT (Anti-Cloak™ Technology)
ZZ
MW (Microwave) Range
Trimmer
Defines the microwave channel range.
MINIMUM
25%
50%
65%
85%
MAXIMUM
TRIMMER
(MW is defined by the trimmer setting on the PCB)
ZZ
Alarm Logic
PIR and Microwave
Determine the detector’s logic of defining an alarm.
PIR & MW
(and Microwave) – An alarm is activated when both PIR
and MW channels detect an alarm (AND Logic).
PIR / MW
(or Microwave) - An alarm is activated when either PIR
or MW channels detect an alarm (OR Logic).
ZZ
Lens Type
Wide Angle
Defines the actual lens of the detector.
WIDE ANGLE
BARRIER / LONG RANGE
ZZ
Anti-Mask
Enable
Defines the operation of Anti Masking detection.
DISABLE
ENABLE
ZZ
Set/Unset
No
Defines the operation of the LEDs and Anti masking detections while
the detector is set.
Active IR AM and Proximity AM (Anti masking) is enabled.
LEDs behave according to the LEDs parameter definition.
YES
– Active IR AM and Proximity AM (Anti masking) is disabled
LEDs are disabled.
Содержание LightSYS
Страница 1: ...Installation and Programming Manual ...