Installing Bus Devices
Page 42
To Power Supply
To Mains Ground
Blue
B
lu
e
B
ro
w
n
Green-Yellow
18 AWG (at least)
Brown
Mains
Figure
3-10: SMPS – AC & Ground Connection
7.
Set the SMPS jumpers and the DIP switches as follows:
Mod-
ule
DIP switch
Description
Power
Supply
PS/SW1-SW3
Used to set a unique ID number for the bus module for
communication purposes.
PS/SW4
Enables/disables Power Supply – LightSYS
communication.
On
(up): Communication enabled.
Off
(down): Communication disabled
Progra
mmabl
e
Output
PO/ SW1-SW3
Used to set a unique bus ID number for the PO module
located on the SMPS board.
PO/SW4
Enables/disables PO module – LightSYS communication.
On
(up): communication enabled.
Off
(down): communication disabled
Note:
When PS/SW4, or PO/SW4 is Off, the ID number defined by SW1-SW3 is not
recognized by the LightSYS and can be used for the connection of another
accessory of the same category. The PO/PS LED will flash since there is no
communication with the main panel.