Engineer Programming
Page
147
Quick Keys
Parameter
Default
Range
1st Backup 2nd3rd: Reports to ARC 1. If communication is not
established calls ARC 2. If communication is not established again calls
the ARC.
1st Backup 3rd Call 2
nd
: Reports ARC 1. If communication is not
established calls to ARC 3. In addition it will also call ARC 2.
2nd Backup 3rd Call 1st: Reports to ARC 2. If communication is not
established calls ARC 3. In addition it will also call ARC 1
.
Report Codes
Enables you to view or program the codes transmitted by the system to
report events (for example, alarms, faults, restores, supervisory tests,
and so on) to the alarm receiving centre.
The codes specified for each type of event transmission are a function of
the central station’s own policies. Before programming any codes, it is
important to check the central station protocols. Reporting codes are
assigned by default, according to the selected communication format SIA
or contact ID.
Assigns a specified report code for each event, based on the reporting
format to the alarm receiving centre. An event that is not assigned with a
report code will not be reported to the alarm receiving centre. For list of
report events refer to
Using a double-zero (00) for any event will prevent a report from being
generated.
Configuration SW
The
Configuration Software
menu contains parameters that enable the configuration
software to establish connection with the system.
Quick Keys
Parameter
Default
Range
Security
Enables you to set parameters for remote communication between the
technician and the system using the configuration software