Mounting and Wiring
Page
25
+ BELL: To connect to the self
activated bell’s (SAB) positive hold
off input.
- LS: To connect to the SAB negative
hold off input.
BELL TMP: To connect to the bell
input of the SAB Unit.
Wiring Programmable outputs
The LightSYS programmable outputs support a variety of power-line device
activation, whether resulting from: time dependency, external input, or device sensor.
As detailed in Chapter 4,
you can program customized device activation
powerfully and granularly.
For additional details, see page 36.
To wire Programmable output 1:
Utility output 1 can be used to activate a self-powered sounder or any other self-
powered device.
Figure
2-8: Wiring U01 for self-powered device
To wire Programmable outputs 2-4:
Connect the device to the PO's as illustrated below:
UO2
External