Engineer Programming
Page
59
Step 3: Set Bus Zone Basic Attributes
1.
From the main Engineer menu select
[1] Zones > [1] Parameters >
[1] One by One
.
2.
Select the zone number that the bus zone was assigned to and press
.
3.
Configure the parameters for the relevant bus detector.
Note:
In the zone designation XY:ZZ the X represent the Bus Expander ID as set by its dip
switches.
Step 4: Programming the Bus Detectors Advanced Parameters
1.
From the main Engineer menu select
[2] Zones > [1] Parameters >
[2] By Category > [7] Advanced > [4] BZ Parameters
.
2.
Select the zone number that the bus zone was assigned to and press
.
3.
Configure the parameters for the relevant bus detector.
Exiting Programming Mode
1.
Set SW1 – 2 (Default) to OFF position.
2.
Close the main box in order to prevent Front Tamper Alarm.
3.
Press [*] repeatedly to return to ‘Main Menu’.
4.
Press
>
to
Exit
and
SAVE
your settings.
Note:
The system will not allow exit from the Engineer mode if a ‘Tamper’ or ‘System
Troubel’ condition exists. Correct any tamper and/or system fault conditions before
attempting to exit the Engineer mode.
Restoring Manufacturer's Programming Defaults
You may find it useful to be able to remove all or some changes made to the main panel's
programming and restore the default settings provided by the manufacturer.
To restore the main panel to the manufacturer's defaults:
1.
From the engineer Programming menu, select:
1)
System
>
5) Setting
>
2) Default Panel
2.
Using the key
select whether to also restore the system labels to the
manufacturer defaults and press
to confirm
.
3.
Using
the key
to toggle
Y
.
4.
To save your settings exit
the programming mode.