Engineer Programming
Page 94
Quick Keys
Parameter
Default
Range
When using this zone you should connect the alarm wiring of this zone
(usually the auxiliary contact of a door) to an external key box and the
tamper wiring to the housing switch.
ZZ
KeySwitch Set
This zone is used by financial institutions such as cash distribution
centers and banks to control the setting of the vault door or treasury
department entrance.
Use this zone for instant setting of the partition in which the zone is
allocated. This zone cannot perform unsetting operation.
ZZ
KeySwitch Delayed Set
Same as the
KeySwitch Set
(
ZZ
)
type but the setting will be
delayed following exit delayed time.
Sound
This menu enables you to program the sound produced when a systems
zone triggers and alarm. Reports to the alarm receiving centre are not
affected by the option of this menu.
The following sound can be selected:
Silent
: Produces no sound
Bell Only
: Activates the bell sounders for the duration of the Bell
Timeout period, or until a User Code is entered
Buzzer Only
: Activates each keypad's internal piezo buzzer.
Bell + Buzzer
: Activates the bell sounders and the keypads' buzzers
simultaneously
Door Chime
: The Door Chime parameter is used as an audible
sounder to indicate the violation of a zone(s), as follows:
o
If the system is UNSET, the system's keypad buzzers make three
momentary sounds whenever the zone is violated.
o
If the system is SET, only the bell sounders produce the alarm.
A different sound can be defined according to the system status as
follows
Quick Keys
Parameter
Default
Range
At Set
Set the sound produced when a system's zone triggers an alarm while
the system is set in Full Set.