8 | Faults
RINCO ULTRASONICS AG
106 / 137
BA_Standard3000_GB_V5.1_36566
S.:
No. Error message
Cause
Measures
002: 009 Full scale of output stage
has been reached.
The output stage is opera-
ted with maximum modulati-
on
▪ Check the mains voltage if 100%
amplitude is being used
▪ Reduce contact pressure on
workpiece
▪ Replace generator module
002: 010 Converter not connected.
The converter is not con-
nected to the generator
▪ Check connection cable for proper
seating
Tab. 31:
Error generator