Error press
S.:
No. Error message
Cause
Measures
003: 000 Error travel measurement
An error has occurred
during travel measurement
▪ Check the travel measurement
according to the travel measure-
ment calibration
▪ Replace travel measurement
device
003: 001 Valve errors
Error while actuating the
valves
▪ Check valves ("System status"
menu)
▪ Replace valve if necessary
003: 002 Error two-hand release
The two-hand release
displays an error
▪ Check fuse in two-hand release
▪ Check connection ("System status"
menu)
▪ Replace two-hand release
003: 003 Rest position of press not
reached
The rest position (=upper
end position of the cylinder)
has not been reached
▪ Check cylinder positions ("System
status" menu)
▪ Check connections
▪ Replace cylinder switch
003: 004 Error safety switch
The safety switch(es) of the
press is/are defective
▪ Wire break in line
▪ Check safety switch ("System
status" menu)
▪ Check connection ("System status"
menu)
▪ Replace safety switch
003: 005 Maximum cycle time has
been reached
The maximum cycle time
(welding time) of 10 s has
been exceeded
▪ Change the parameter settings so
that the max. cycle time can be
observed.
003: 006 Welding process terminated The welding process has
been terminated
▪ Two-hand release was released
before the safety switch had been
reached
003: 007 Error trigger set
The set trigger force was
reached before the safety
switch was reached
▪ Check parameter settings and
change if necessary
▪ Check travel measurement system
▪ Check force measurement system
Tab. 32:
Press errors
Sound enclosure errors
S.:
No. Error message
Cause
Measures
004: 000 Error during initialisation
Initialisation of the SSK
failed
▪ Check actuators and sensors
▪ Check connection to SSK
▪ Check generator
▪ If the error occurs permanently, the
generator must be replaced
8.5.2
8.5.3