6 | Operation
RINCO ULTRASONICS AG
72 / 137
BA_Standard3000_GB_V5.1_36566
ADG with special actuators (automatic start mode)
0
1
2
3
4
5
6
Start
START_1, 2_EXT_IO_IN
(STO_2_1 – Pin 3, 4)
START_OUT
(STO_2_2 – Pin 12)
START_CONFIRM_IN
(STO_2_1 – Pin 11)
MV_OUT
(STO_2_2 – Pin 13)
START_RETURN_OUT
(STO_2_2 – Pin 14)
TRIGGER_IN
(STO_2_1 – Pin 10)
RESTPOS_OUT
(STO_2_2 – Pin 10)
US_ACTIVE_OUT
(STO_2_2 – Pin 9)
READY_CONFIRM_IN
(STO_2_2 – Pin 12)
READY_OUT
(STO_2_2 – Pin 8)
Pv
Abbildung 45
Fig. 45:
ADG with special actuators
0 > 1 Forward stroke fast
1 > 2 Stroke braked
2 > 3 Force build-up trigger
3 > 4 Melt
4 > 5 Solidification
5 > 6 Return stroke
By actuating the inputs START_1_EXT_IO_IN and START_2_EXT_IO_IN,
the process is started which is signalled by the output START_OUT.
The two start inputs START_1,2_EXT_IO_IN must be actuated until
START_RETURN_OUT is output to signal that the press is on its return
stroke.
With this application, the options "Start confirmation" and "Ready confirmati-
on" are enabled.
The power loss measurement (Pv) is triggered only after the input START_
CONFIRM_IN is available.
Similarly, the ready notification for the next welding cycle READY_OUT is
not signalled until the input READY_CONFIRM_IN is available.
6.2.4
Signals
Process steps
Fig. 46:
Process sequence
Functional description