RINCO ULTRASONICS AG
Operation | 6
BA_Standard3000_GB_V5.1_36566
79 / 137
Block
Access
Description
Start confirmation:
If this option is enabled, the input START_CON-
FIRM_IN must be activated so that the generator
starts the cycle.
Ready confirmation:
If this option is enabled, the input READY_CON-
FIRM_IN must be activated so that the generator
starts the cycle and the output READY_OUT is set.
Workpiece counter output:
▪ Pulse: A 300 ms long high pulse signals a
correct welding.
▪ Signal: After the next correct welding, the output
is set to a high level until the start of the next
cycle.
Reject counter output:
▪ Pulse: A 300 ms long high pulse signals a faulty
welding.
▪ Signal: After the next incorrect welding, the
output is set to high until the start of the next
cycle.
Online data window:
During the cycle, an information window is open
that shows the travel, trigger and power.
Statistics:
If Statistics is switched on, 'Continuous,' 'Groups'
and 'Values' can be selected in the "Welding"
(home) window. As a result, the F1 button is
assigned with a new function. (See chapter
Statis-
tics [
}
83]
)
Tab. 14:
System functions (PIN) Options 2
Block
Access
Description
Sonotrode
Power loss measurement:
Select time of measurement
Max. power loss:
Max. limit value
▪ 10 % to 40 %
Interval Pv measurement:
Measurement interval
▪ 0 to 9999; 0 (no measurement)
Tab. 15:
System functions (PIN) of sonotrode
Sonotrode