Page 11 of 88
Power Supply and Thermal Management
RockNet devices feat ure redundant switch-mode power supplies suitable for world-wide operation.
The power supplies are modular and therefore easy to replace in case of failure.
The replacement of power supplies is done by Media Numerics Ltd. or one of its authorized distribu-
tors or dealers and may under no circumstances be done by the user.
Two locking IEC connectors on the back panel of the device are standard.
Built in silent running fans add to the component reliability and enable ultimat e rack space efficiency.
1
Power Supply A
IEC
connect via locking IE C connector of provided power supply cord
2
Power Supply B
IEC
connect via locking IE C connector of provided power supply cord
3
Wordclock IN
BNC
connect via B NC for external sync of RN.300 device (Sync Master
only)
4
Wordclock OUT
BNC
connect via B NC for synchronizing external equipment to RN.300
5
GP I/O
DB9
for future use, currently no functionality
6
Fan
permanent silent running fan if device is connected to mains
power
Easy Installation
RockNet is an integrated system that does not require any third party products.
Only two types of cables are necessary to hook up a network:
•
microphone cables with XLR (male/ female) and
•
CA T.5 net work cables with RJ45 (Ethercon® )
RockNet devices do not require breakout panels or any special cables and connectors.
Up to 99 devices can easily be added to a single network.
All configuration information is stored in the device, e. g. Quad assignment, channel parameters, chan-
nel and device labels (via RockWorks), sync settings, etc.
USO
RESTRITO