RB051007
T
echnical
B
ulletin
PAGE: 1/4
Model:
Model TH-C1
Date:
6-Jul-05
No.:
RB156004
Subject:
Notes for Installation - 2
Prepared
by:
H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other ( )
Important:
The following symptom is the same as the one announced in RTB RB051007a
(Model U-C1). However, if the development unit is not installed correctly in the field, the
production line solution in RTB RB051007a cannot prevent the symptom. Therefore at
machine installation, make sure to do the check in the “Solution” below.
SYMPTOM
A blank area (
sample 1
) or blank patches (
sample 2
) may appear on the side edges of
the paper.
Note:
Also, because of this problem, the ID sensor pattern on the OPC is blank. If the
machine reads this, it can change the process control conditions.
CAUSE
The gears of the development unit do not engage the mainframe gears correctly.
Note:
This can occur at toner cartridge replacement, when the old toner cartridge is not
pulled out correctly.
Sample 1
Mainframe gears
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...