T
echnical
B
ulletin
PAGE: 1/
2
Model:
Model TH-C1
Date:
21-Jun-06
No.:
RB156030
Subject:
Charge Corona Harness
Prepared
by:
H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
)
Important Note for When Replacing the Charge Corona Unit
1. When you install the charge corona unit,
do not straighten
the cleaner motor harness
if this harness is
white
.
From May 2006 production, the material of the harness was changed to a more
environmentally-friendly type. The new harness is
white
and the material is
harder than the black harness.
The new harness is bent at the factory. This is to make sure that harness does
not push the quenching lamp (QL).
If you straighten the white harness, SC305 can occur.
2. If SC305 occurs when you install the charge corona unit:
This means the white harness is straight, and is pushing on the QL/holder connection
(see the photos on the next page).
Action:
Correct the QL position and bend the white harness so that it does not push
the QL.
Black harness
White harness
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...