T
echnical
B
ulletin
PAGE: 2/2
Reissued: 29-Jun-07
Model:
Model TH-C1
Date:
5-Oct-05
No.:
RB156010b
Symptom Corrected
Version
Important note:
Websys firmware Ver 1.02 or later must be used with NIB firmware Ver 4.17
or later and controller firmware Ver 1.08 or later.
Changed :
The following settings have been added to WIM [Configuration->Device
Settings->System]:
1. Display IP Address on the Display Panel - Displays the device's IP address
on the panel.
2. "Permit ROM Update" - Enable/Disable firmware updates.
3. "Print Priority" function
The device now supports the ROM update function via WIM. [Configuration-
>ROM Update]
Web Image Monitor is available in Korean.
Some menu items in WIM are improperly displayed.
1. SSL settings in German.
(Wrong) [Verschlüsselung/ Text löschen] [Chiffretext/ Text löschen]
(Correct) [Verschlüsselung/ Klartext] [Chiffretext/ Klartext]
2. Administrator Authentication Management in Czech
(Wrong) Správa autorizace uživatele
(Correct) Správa autorizace administrátora
Fixed: LDAP Authentication does not work if configured using the 'LDAP
Server 3, 4 or 5' settings from WIM. These settings work correctly if set from
the operation panel.
V1.02
First release
V1.00
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...