T
echnical
B
ulletin
PAGE: 1/2
Model:
Model TH-C1
Date:
4-Oct-06
No.:
RB156035
Subject:
Front Door Safety Switch
Prepared
by:
H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other ( )
SYMPTOM
The front door safety switch breaks when the front door is closed with too much force.
Note:
This does not occur if the front door is closed with the normal amount of force.
CAUSE
The operator closes the front door with too much force, and the front door switch boss
pushes too strongly on the safety switch.
SOLUTION
Production line
The projection on the inside of the front door was made longer. As a result, the projection
stops the switch boss before the switch boss pushes the switch too far.
Note:
The change was applied to the following parts, but the P/N are still the same.
See the cut-in S/N below.
Part
number
Description Q’ty
Page Index Note
B1541250
Door: Front (EU)
1
9
1
B1561259
Door: Front (NA/Asia)
1
9
1
The length of the projection was
increased until it touches the door.
Projection
Gap ensures the
switch is not pushed
too hard
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...