T
echnical
B
ulletin
PAGE: 4/5
Reissued: 20-Jan-06
Model:
Model TH-C1
Date:
19-Jul-05
No.:
RB156005c
Symptom Corrected
Version
The default for the following SP modes (image transfer current) was
changed. This is to prevent residual images on small paper types.
Paper Transfer LL1
・
SP2-310-3
・・・
25
→
22: Normal/1
st
/210-256
・
SP2-310-7
・・・
26
→
21: Mid/1
st
/257-296
・
SP2-310-8
・・・
26
→
23: Mid/1
st
/210-256
・
SP2-310-17
・・・
30
→
27: Normal/2
nd
/257-296
・
SP2-310-22
・・・
31
→
28: Mid/2
nd
/257-296
Paper Transfer LL2
・
SP2-311-3
・・・
29
→
25: Normal/1
st
/210-256
・
SP2-311-7
・・・
29
→
23: Mid/1
st
/257-296
・
SP2-311-8
・・・
30
→
26: Mid/1
st
/210-256
・
SP2-311-17
・・・
29
→
28: Normal/2
nd
/257-296
・
SP2-311-22
・・・
30
→
29: Mid/2
nd
/257-296
Paper Transfer NN1
・
SP2-312-3
・・・
32
→
27: Normal/1
st
/210-256
・
SP2-312-7
・・・
31
→
23: Mid/1
st
/257-296
・
SP2-312-8
・・・
33
→
28: Mid/1
st
/210-256
Paper Transfer NN2
・
SP2-313-7
・・・
31
→
24: Mid/1
st
/257-296
・
SP2-314-7
・・・
31
→
24: Mid/1
st
/257-296
・
[0.1 ~ 70.0 / / 0.1
μ
A/step]
Note: In addition to this BICU version, be sure to update the main unit
controller firmware to V1.04 or later.
A new SP mode was added to turn on the development fan at job end
(default: the fan is turned Off at job end). This is to prevent dirty background,
which can occur in high-temperature/high-humidity conditions.
SP2-983-2: Development unit fan continue
[0 ~ 900 /
0
/ 10 s/step]
A new SP mode was added to adjust the step for counting the number of
A4/LT SEF developments for Toner Refresh mode.
Note:
-
Usually, 1 A4/LT SEF sheet is counted as 1, but for machines which use
this paper as their main size, a setting of “1.2”.
-
This setting of this SP mode does not change the value of the machine
counters.
SP3-972-1: Development .counter for A4/LT SEF
[1 or 1.2 count/
1
/ ]
V1.021
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...