T
echnical
B
ulletin
PAGE: 3/3
Reissued: 14-Apr-06
Model:
Model TH-C1
Date:
19-Jul-05
No.:
RB156006b
Symptom Corrected
Version
Fixed: RC gate may sometimes fail to update the firmware.
Documents with any of the below attributes that are printed from the
document server using Magazine, Booklet, or Stamp may cause an SC687
error.
- Document size: [B4] or [Legal]
- PS driver: [Color] setting is [Super Fine].
- RPCS driver: Resolution is [1800 x 600 dpi] (default)
- PCL driver: Resolution is [600 dpi] and the [Gradation] setting is [Standard].
An SC672 error might occur if documents are stored to the Document Server
using the Fax or Scanner applications of a device with the MLB option. This
only occurs if storing the job is attempted just after power on.
V1.07
Print and Copy speed is decreased when the data overwrite security unit
is
installed.
SC672 misdetection.
Modified in accordance with the BICU v1.04 modification. For details, please
see RTB #RB156005.
Note: In addition to this main unit controller version, be sure to update the
BICU firmware to v1.05 or later.
V1.06
The firmware cannot be updated with RC Gate if “Machine Management” is
OFF (User Tools – Administrator Tools).
Occurrence conditions of SC870 were changed to prevent unnecessary
occurrences (Scanner and address in the HDD communication mal function).
Modified in accordance with the BICU v1.04 modification. For details, please
see RTB #RB156005.
Note: In addition to this main unit controller version, be sure to update the
BICU firmware to v1.04 or later.
V1.05
The machine freezes after the BICU and/or FCU firmware is updated via RC
Gate.
The machine cannot connect to RC Gate at installation.
The Start key does not turn green.
Conditions:
-
The Capture function is used with the MLB
-
User authentication is enabled
-
The System Auto Reset Timer, Scanner Auto Reset Timer and Auto
Logout Timer are all set to the same value
Modified in accordance with the BICU v1.03 modification. For details, please
see RTB #RB156005.
Note: In addition to this main unit controller version, be sure to update the
BICU firmware to v1.03 or later.
V1.04
SC990 occurs if a user starts a print job for a Document Server document,
logs out during the job, and then another user logs in.
The operation panel freezes if a user logs in through User Authentication,
logs off just after starting a job, presses the C/S key, and then presses the
Job Reserve key.
V1.03
First release
V1.02
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...