T
echnical
B
ulletin
PAGE: 1/5
Reissued: 20-Jan-06
Model:
Model TH-C1
Date:
19-Jul-05
No.:
RB156005c
RTB Reissue
The items in bold italics have been added.
Subject:
Firmware History - BICU
Prepared by: H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other (Firmware History)
This is to inform you of the BICU firmware history.
Part No.
Program name
B1545552
L
B1545552L.fwu V1.11:03
February
Production
‘06
K B1545552K.fwu
V1.10:03
December
Production
‘05
J B1545552J.fwu
V1.09:03
November
Production
‘05
H
B1545552H.fwu
V1.08:03
October Production ‘05
G B1545552G.fwu
V1.07
August
Production
‘05
F B1545552F.fwu
V1.06
July
Production
‘05
E B1545552E.fwu
V1.05
June
Production
‘05
D B1545552D.fwu
V1.04
May
production
‘05
C
B1545552C.fwu
V1.03
April production ‘05
B
B1545552B.fwu
V1.021
March production ‘05
A
B1545552A.fwu
V1.011
-
February production ‘05
Symptom Corrected
Version
A registered User Color cannot be copied after the machine recovers
from Low Power Mode or after the operation switch is turned Off/On.
The ARDF sometimes detects a U.S. standard size as a European
standard size (e.g. an LT original is detected as A4).
V1.11:03
The machine detects the toner end signal from the BK toner end sensor, and
then triggers the Toner End condition. Normally, this signal is not used for
Toner End control, so this BICU version ignores the signal.
An SC545 misdetection occurs when the machine recovers from Energy
Saver mode or when the main switch is turned ON.
It is possible to set Sp6-006-4 to a value of –3.0(mm) to –5.0(mm), even
though the setting range is –2.5(mm) to +5.0mm.
Note: As a result, lines appeared on the copy surface when the value was set
to –3.0 to –5.0
Other change:
The machine performs Process Control once a day (low CV machines).
Note: With previous versions, the machine performed Process Control when
the fusing temperature increases from 60 degrees or less (recovery from the
energy saver mode).
V1.10:03
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...