T
echnical
B
ulletin
PAGE: 1/3
Model:
Model TH-C1
Date:
28-Feb-06
No.:
RB156024
Subject:
Pinched Harness
Prepared
by:
H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other ( )
SYMPTOM
The BICU board is defective, or the controller board is defective and SC838 occurs
(Verification Error).
CAUSE
A short circuit occurs with the +5VF or +5VE line in the harness between the IO board and
BICU board (P/N B1545408).
z
+5VE short-circuit: The controller board may be defective and SC838 occurs
z
+5VF short-circuit: The BICU board may be defective
Note:
The short circuit can be caused at the factory or in the field (see
Solution
).
Damaged harness
between IO board and
BICU board
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...