T
echnical
B
ulletin
PAGE: 1/3
Reissued: 7-Oct-05
Model:
Model TH-C1
Date:
19-Jul-05
No.:
RB156006a
RTB Reissue
The items in bold italics have been added.
Subject:
Firmware History - Main Unit Controller
Prepared
by:
H.K.
From:
1st Tech. Support Sec. Service Support Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Other (Firmware History)
This is to inform you of the Main Unit Controller firmware history.
Part No.
Program name
B1545550
B1545550F.fwu V1.08
October
production
‘05
B1545550E.fwu V1.07
August
production
‘05
B1545550D.fwu
V1.06
June production ‘05
B1545550C.fwu V1.05
May
production
‘05
B1545550B.fwu V1.04
April
production
‘05
B1545550A.fwu
V1.03
March
production
‘05
- B1545550.fwu
V1.02
-
February
production
‘05
Symptom Corrected
Version
Changed:
1.The following SPs have been newly added.
- SP5-886-001 (ROM Update)
Allows to access the ROM by the Remote Firmware Update function
[0 ~ 1/ 0 / 1/step] (0: Yes, 1: No)
- SP5-005-001 (IP Address Display)
Display the IP Address on the LCD.
[0 ~ 1/ 0 / 1/step] (0: No, 1:Yes)
Note:
These above functions are only available if all 3 of NCS firmware ver
4.17 or later, Controller firmware Ver 1.08 or later and Websys firmware
Ver 1.02 or later have been applied to the device.
Fixed: Users cannot log into an MFP via Windows Authentication using
a domain controller in a different subnet unless WINS is enabled
(GFPR#RC05060014).
Fixed: If the device receives more than 300 login attempts without
cycling the power, the error message SC991 will be displayed on the
operation panel and users will not be able to login to the device. This
can happen no matter where the logins attempts are made from the
operation-panel, WIM, in print data.
Fixed: The error code for Remote firmware update is remained even if
the Remote Firmware Update is successful.
Fixed: The username and password will still be contained in the fields
when someone opens the login screen by pressing the User Tools
button. This occurs if username and password are left in the field
without logging in.
V1.08
Содержание TH-C1
Страница 33: ...Technical Bulletin PAGE 13 15 Model Model TH C1 Date 2 Jun 05 No RB156003 Ribs...
Страница 38: ...RB051007 Technical Bulletin PAGE 3 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 39: ...RB051007 Technical Bulletin PAGE 4 4 Model Model TH C1 Date 6 Jul 05 No RB156004...
Страница 96: ...Technical Bulletin PAGE 3 3 Model Model TH C1 Date 28 Feb 06 No RB156024 Protective electrical tape...
Страница 170: ...Technical Bulletin PAGE 3 6 Reissued 23 Jul 07 Model Model TH C1 Date 11 Jul 06 No RB156033a Fusing Unit PCU...