PART V TROUBLESHOOTING
5-5
ENGLISH
Fig. 5.1.3-8 Plug the fan motor connection to the main
circuit board and check the fuse. If the fuse is still
blown out, you will need to check the fan motor
capacitor and fan motor.
1-Power cord connection
2-High voltage power supply connection
3-UV lamp cord connection
4-Fan motor connection
5-Negative ion generator connection
Finally check the fan motor connection
Plug the fan motor (4#) connection to the main circuit board and start the unit by pressing the POWER button on the
control panel. Press the SPEED button (Fig. 5.1.3-8). If the fuse is suddenly blown out, you will need to replace the motor
capacitor. See
6.8 REPLACE THE FAN MOTOR CAPACITOR
. After replacing the motor capacitor, the fuse is still blown
out, you have to replace the fan motor. See
6.7 REPLACE THE FAN MOTOR
.
1
3
4
5
1
3
4
5
2
2
An Important Notice:
For the units starting with ser.#
J200
xxx
(Main circuit board-A ), you can check all the
connections in the similar way with the new
main circuit board-B units.
For the main circuit board-A (Left picture):
1-Power cord connection
2-High voltage power supply connection
3-UV lamp cord connection
4-Fan motor connection
5-Negative ion generator connection
Main circuit board-A