ENGLISH
2-1
FEATURES AND SPECIFICATIONS
The air purifier functions as an air cleaner by helping to disinfect
airborne microorganisms and removing particulates from the air.
The centrifugal fans of the unit draw air through the front panel on
the front of the unit. Then it passes through the Pre-filter, the
Electronic cell, the Activated carbon filter and the UV-Photo
catalytic sterilization chamber. The purified air is then released
through the outlet on the top of the unit.
The Air is Cleansed in Six Stages:
1. The Pre-filter traps large dust particles.
2. The two-stage electrostatic precipitator (Electronic cell) captures
airborne particles, as small as 0.01 microns. In the ionizing section
of the electronic cell, billions of microscopic particles become
electrically charged as they pass through the powerful electric field.
The collector plates immediately attract and collect these charged
dust and dirt particles.
3. The activated carbon filter absorbs and reduces odors,
chemicals and gases, removes tobacco smoke, the smell of food
and other odors.
4. The UV sterilization chamber kills bacteria and viral
microorganisms such as influenza, TB and Legionnaire's Disease
as well as other harmful contaminants.
5. When UV light hits the photo catalytic filter; it creates e- and h+,
which have an excellent effect in the decomposition of odors.
6. The unit also generates negative ions that freshens the room air.
Front View
Side View
Fig.2.1-1 The front and side view of 200T.
Features
Multi-Stage Filters
The unit utilizes a two-stage electrostatic
precipitator combined with a Pre-filter (for
large particles), an Activated Carbon Filter
(for odors and gases), UV germicidal light
(killing airborne pathogen), a Photo catalytic
filter (removes VOC's) and a Negative ion
generator.
Automatic Function
The gas sensor (odor sensor) can let the
unit automatically select the appropriate fan
speed depending on the air quality detected.
Filter and UV Lamp Replacement
Indicator
The "Filter life" and "UV Lamps"
replacement indicators tell you when to
replace the Activated Carbon Filter and the
UV lamp.
Safety Micro-Switch (Interlock Switch)
This air purifier is equipped with a safety
interlock switch (Micro-safety switch) that
will turn the unit off if the front panel is
removed while the unit is running.
Easy Maintenance and Low Cost
When the electrostatic precipitator
(Electronic cell) needs to be washed or the
filters need to be replaced, simply open the
front panel and pull out the electronic cell or
old filters and put the new or clean one in.
No screws, hooks or tools are required. The
electronic cell captures small particles on
aluminum plates that are simply rinsed off in
the sink. There are no expensive filters to
replace.
PART II AIR CLEANING TECHNOLOY OF THE UNIT
Standby Power
In order to operate the electrical circuits while the power plug is inserted in the
wall outlet, this product consumes about 4.6W of standby power. For energy
conservation, unplug the power cord when the unit is not in use.
Table 2. Specifications of the unit.
Model No.
Power Requirement
Rated Power
Fan Motor
Fan Speed CFM
Applicable Floor Surface
(Ceiling height 8')
Noise Level
Negative Ion
UV Lamp
Cord Length
Dimensions
Weight
RespirAide 200T
120V,60Hz,0.5A
55W
120V,60Hz,0.2A
H-300,M-135,L-88
1 air exchange per hour: 2257 sq.ft.
2 air exchanges per hour: 1129 sq.ft.
5 air exchanges per hour: 451 sq.ft.
19 air exchanges per hour: 10x12 sq.ft.
<45dB
3x10
6
pcs/cc
6W
2.5m (8.3 ft)
82cm (H)x48cm (W)x22cm
25.7kg (55 lbs)
*The applicable floor surface area is appropriate for operating
the unit at maximum fan speed.
Содержание R200T
Страница 69: ...ENGLISH NOTES ...