*Notice: The information in this document is subject to change without notice
Tsi301
Notes
Tsi301 HyperTransport to PCI User Manual
2-6
2.8 Calibrator Logic Signals
Lx_RREF_GND/Lx_RREF
Bidirectional
These signals are used by the HyperTransport calibrator logic. A resistor should be placed between these
two pins. The resistor value should be equal to half of the differential impedance of the HyperTransport
signals, which is 100 ohms +/- 10%.
Note:
The LDT_RREF_GND should not be connected to ground.