The new values remain set even when you switch off the display
and are applied to all fishfinder windows.
Fishfinder TVG (Time Varied Gain)
The Time Varied Gain (TVG) function reduces the amount of clutter
in the fishfinder display by varying the gain throughout the column of
water. This function is useful for reducing the appearance of ‘noise’.
• Increasing the TVG value increases the maximum depth to which
TVG is applied. A high value decreases the gain in shallow water
so that only the strongest echoes are displayed.
• Decreasing the TVG value reduces the maximum depth. A low
TVG value has little effect on gain in shallow water.
TVG adjustment can be made automatically or manually.
Adjusting the fishfinder time varied gain
From the fishfinder application:
1. Select
Menu
.
2. Select
Adjust Sensitivity
.
3. Select
TVG
.
4. Select the
TVG
menu so that Man is highlighted.
Selecting the TVG menu will switch between TVG Auto and
Manual modes.
5. Use the
Rotary Control
to adjust the TVG to the required setting.
Note:
TVG has no effect in fishfinder simulator mode.
Fishfinder color threshold
The color threshold setting determines the range of colors used on
screen. The effect of this is to set a color threshold below which
targets are not shown. For example a low setting would result in
only the strongest (orange and red) targets being displayed.
Adjusting the fishfinder color threshold
From the fishfinder application:
1. Select
Menu
.
2. Select
Adjust Sensitivity
.
3. Select
Color Threshold
.
4. Select the
Color Threshold
menu so that the setting is
highlighted.
5. Use the
Rotary Control
to adjust the color threshold to the
required setting.
6. Press the
Ok
button, or select the
Color Threshold
menu again
to confirm the setting.
Fishfinder power
The power setting controls the power level of the transducer.
Power options:
•
Auto
. This is the default setting. When it is selected the DSM
automatically determines the required power setting based on the
current depth, speed, and (bottom) signal strength. .
•
Manual
. If you wish to manually adjust the power to suit current
conditions, you can adjust the power level between 0% and
100%, in 10% increments. Lower power levels are normally used
in depth ranges less than 8 ft. (2.4 m) and higher power levels are
typically selected for depths greater than 12 ft. (3.7 m).
Adjusting the fishfinder power
From the fishfinder application:
1. Select
Menu
.
2. Select
Adjust Sensitivity
.
Using the fishfinder
203
Содержание e7
Страница 2: ......
Страница 4: ......
Страница 14: ...14 e7 e7D User reference ...
Страница 18: ...18 e7 e7D User reference ...
Страница 62: ...62 e7 e7D User reference ...
Страница 124: ...124 e7 e7D User reference ...
Страница 132: ...132 e7 e7D User reference ...
Страница 174: ...174 e7 e7D User reference ...
Страница 211: ...Note The Shallow Limit cannot be set to greater than the Deep Limit Using the fishfinder 211 ...
Страница 248: ...248 e7 e7D User reference ...
Страница 249: ...Chapter 14 Using video Chapter contents 14 1 Video application overview on page 250 Using video 249 ...
Страница 260: ...260 e7 e7D User reference ...
Страница 272: ...272 e7 e7D User reference ...
Страница 278: ...278 e7 e7D User reference ...
Страница 316: ...316 e7 e7D User reference ...
Страница 317: ...Owner notes ...
Страница 318: ...Owner notes ...
Страница 319: ......
Страница 320: ...www raymarine com ...