9.2 Digital radar scan speed
SuperHD open array radars with software version 3.23 or above or
HD digital radomes support multiple scan speeds.
Radar scan speed is set up using the Radar Set-up menu. When
the system detects a scanner that is capable of operating at both 24
RPM and 48 RPM, 2 options are provided for scanner speed:
• 24 RPM
• Auto
If you have a digital radar scanner that only operates at 24 RPM,
the scanner speed option is disabled. If the scanner speed option
is enabled, you must select the Auto option if you want to use the
higher scan speeds. This option automatically switches between the
24 RPM and 48 RPM scan speeds as appropriate.
Selecting radar scanner speed
The speed option requires a 48 RPM compatible Raymarine HD
digital radome or Raymarine SuperHD digital open array radar
scanner.
Select your radar scanner speed from within the radar application.
1. Select
Menu
.
2. Select
Scanner Set-up
.
3. Select
Scanner Speed
4. Select the required scanner speed:
• Auto
• 24 RPM
The Auto option automatically selects the appropriate speed
for your radar range. 48 RPM is used at radar ranges of up
to 3 nm. It provides an increased refresh rate, which is useful
at high speed or in areas where you have large numbers of
radar targets. At radar ranges of greater than 3 nm the display
switches the radar speed to 24 RPM.
9.3 Radar scanner status symbols
The radar scanner power mode status is indicated in the databar.
Symbol
Radar
power
mode
Description
Transmit
(TX)
Rotating icon, signifying that the scanner is
on and transmitting. When SCANNER is
set to ON, select this mode to activate the
scanner. This is the usual mode of operation.
Standby
(STBY)
Static icon, indicating that the scanner is on
but not transmitting, and the antenna is not
rotating. The scanner does not transmit and
the radar data is removed from the screen.
This is a power-save mode used when the
radar is not needed for short time periods.
When you return to transmit mode, the
magnetron does not need to warm up again.
This is the default mode.
Off
Scanner powered off when radar not required,
but display is in use for other applications,
such as the chart. When selected, the system
counts down. During this time you cannot
re-power the scanner.
Timed
Transmit
Scanner switches between on/transmitting,
and standby mode. Scanner goes into power
save mode when constant use of radar is not
required.
136
e7 / e7D — User reference
Содержание e7
Страница 2: ......
Страница 4: ......
Страница 14: ...14 e7 e7D User reference ...
Страница 18: ...18 e7 e7D User reference ...
Страница 62: ...62 e7 e7D User reference ...
Страница 124: ...124 e7 e7D User reference ...
Страница 132: ...132 e7 e7D User reference ...
Страница 174: ...174 e7 e7D User reference ...
Страница 211: ...Note The Shallow Limit cannot be set to greater than the Deep Limit Using the fishfinder 211 ...
Страница 248: ...248 e7 e7D User reference ...
Страница 249: ...Chapter 14 Using video Chapter contents 14 1 Video application overview on page 250 Using video 249 ...
Страница 260: ...260 e7 e7D User reference ...
Страница 272: ...272 e7 e7D User reference ...
Страница 278: ...278 e7 e7D User reference ...
Страница 316: ...316 e7 e7D User reference ...
Страница 317: ...Owner notes ...
Страница 318: ...Owner notes ...
Страница 319: ......
Страница 320: ...www raymarine com ...