174
Trouble shooting CM
Edition 10-2008a
No Steam
Attention: Steam above 110°C is not visible, it does not condensate on the
cabinet door!
Wet cooking mode is activated but
no steam is visible
E16: Temperature
DG>180°C
Check for scale build up
E17: Tempe
rature DG<-5°C:
warm up the cabinet with warm
water
Check solenoid valve lling Y1
YES
Close dooe and / or check door
contact switch
NO
Check level electrode S2 with diag-
mostic program (dP8)
Indication „1“?
Unit connected to treated water?
NO
YES
YES
E6: Check sensor steamgenerator
B5 with diagnostic program
(999°C)
E4: Check quenching sensor
B2 with diagnostic program
(999°C)
Change sensor
Check steam heating elements/
SSR with diagnostic program. Mes-
sure current with clamp meter
YES
YES
NO
NO
Door closed ?
Indication H2O OPEN?
Water tap open?
Sediment lter at water con-
nection to unit clean?
Indication E6 or E4?
Indication E16 or E17 ?
NO
Open water tap, clean sediment
lter
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...