17
CM
Edition 10-2008
CM - Sequence of events
Mode: Low temperature steam;
Temp. range 30-99°C (86-210°F)
Function Step
Responsible sensor
1. Select Low temperature steam mode
Set temperature 30-99°C (86-210°F)
2. Select time or core temperature
3. Close cabinet door
Reed switch S3
4. Check water level inside steam generator
Level electrode S2 inside Steam Generatorr
5. Time based preheating of steam generator,
Thermocouple B5 inside Steam Generator
if B5 is below 85°C (185°F);
6. Timer starts after successful preheating
Logic on PCB
(blinking dot in Display)
7. Steam supply until set temperature
Cabinet sensor B1
inside cabinet is reached
8. Hot Air supply (only 50%) when set
Cabinet sensor B1
temperature can not be reached in time
by Steam alone
9. Quenching (set to 70°C/158°F)
Quenching sensor B2
Note: Reduction of fan motor speed
In case the actual temperature is 2°C / 4°F higher than the set temperature for longer than 2
minutes, the fan speed will be reduced automatically.
B1
B3
F4
M4
Y1
Y2
B2
M1
S2
B5
F3
S3
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...