71
SCC
Edition 10-2008a
Diagnostic mode SCC
Test
20 - DIAGNOSTIC
SC Automatic
53min
45sec
60min
Window 3:
- 53min since last SC -automatic
- Pressing Test => time will be set to set time plus 1 minute
Window 4:
- 45sec: Preset SC-duration (20-90sec)
- 60min: Preset SC-time (20-90min)
Calccheck 3,2l: Release volume for indication CalcCheck
Fill 3,6l:
actual measured water content steam generator
Norm 4,2l: Volume when steam generator is new and clean
M6: CleanJet
Pump
Y2:
solenoid valve quenching
M7: Drain valve motor
S12: Micro switch drain valve
M12 Care motor
Y4 Care Solenoid
Display only from Software SCC 04-01-02
21 - DIAGNOSTIC
Volume
Calc-
3,2L
check
Fill Norm
3,6L
4,2L
22 - DIAGNOSTIC
M6 CleanJet Pump
Y2 Quenching Sol.
M6
0 - 1
Y2
0 - 1
23 - DIAGNOSTIC
M7 Drain valve motor
S12 Micro switch
M7
0 - 1
S12
1 - 0
23.1 - DIAGNOSTIC
M12 Care motor
Y4 Care Solenoid
M12
0 - 1
Y4
1 - 0
Содержание Combi Master
Страница 1: ...Edition 10 2008a 1 Training Manual SCC Line SelfCooking Center Combi Master...
Страница 2: ...2 Edition 10 2008a...
Страница 34: ...34 CM Edition 10 2008...
Страница 35: ...35 SCC Edition 10 2008a SCC Control panel...
Страница 47: ...47 SCC Edition 10 2008a Parts identi cation CareControl 1 2 3 3 4 4 11 1 2 3 4 11 4 2 3 1 2 11...
Страница 58: ...58 SCC Edition 10 2008a...
Страница 66: ...66 SCC Edition 10 2008a...
Страница 100: ...100 SCC Edition 10 2008a...
Страница 126: ...126 Gas Edition 10 2008a...
Страница 139: ...Edition 10 2008a 139 UltraVent...
Страница 153: ...153 Common Information Edition 10 2008a...
Страница 166: ...166 Trouble shooting SCC Edition 10 2008a...
Страница 177: ...177 SCC Edition 10 2008a...
Страница 195: ...195 Common Information Edition 10 2008a...