165
Trouble shooting SCC
Edition 10-2008a
Service 120 (Y1, Level electrode)
After Filling steam generator via M12 the steam generator does not fill
with water via the filling solenoid.
Detection: level electrode does not get contact with water; Steam gen-
erator can not be flushed; unit is without function.
Display Service 120
No
Yes
Yes
Test solenoid valve Y1
in Function test 7
Logic error
Check plugs, cable and I/O pcb
Check function, wiring, connection
at level electrode
Solenopid valve opens
Check power supply at
I/O pcb X21
Yes
Check Power supply at auxilliary
contact k1
No
Yes
Open water tap
Reset error by starting Cleanjet
program; Wait 5 min. Swtich unit
OFF and ON and start cleanjet
abort program