156
Trouble shooting SCC
Edition 10-2008a
Service 11 (CDS Sensor)
Actual measured filling volume above reference volume of steam generator
Indication Service 11
Eliminate leak
NO
NO
YES
YES
Water supply from CDS
to steam generator leaking ?
Check valve in the wa-
ter supply line to the steam
generator.
Valve working correctly?
Change valve
Start volume measuring by acti-
vating pumping function,
rst touch function- then service-
and nally key
for emptying steam generator
Level electrode clean,
cable and connector ok ?
Clean electrode, change defective
part
YES
NO